Nacho Family Service Manual 10
LED repeats 5 flash sequence
Check the thermal switch on the lamp housing. Measure the resistance at the switch
(page 19). If the resistance is infinity (open), the thermal switch is bad.
Projector shuts down after detecting high temperature
condition. LED flashes in repeated five-flash sequence.
Replace controller ECA.
(page 40)
Substitute a good power supply and
run projector long enough to know if
that is the problem.
Yes
Is the thermal
switch good?
Replace the exhaust fan
assembly. The thermal switch
is part of the assembly.
(page 37)
No
Solve the
problem?
No
Run the projector long enough to
confirm the problem issolved.
Repeat the diagnosis process.
Yes
Verify that the two exhaust fans are
operating. These fans are not sensed.
(page 20)
High temperature shutdown
LCD Messages
Are both fans
turning?
Remove the top case (page 31), then check the fan
voltages (page 21). If the voltages are good, replace
the exhaust fan assembly (page 37). If the voltages
are bad, replace the controller ECA. (page 44)
No
Yes
Run the projector long enough to
confirm the problem issolved.
Repeat the diagnosis process.